LOOPFORM

Technical Specifications

Everything an architect needs to spec us.

Materials, sizes, finishes, fire-rating pathway, structural coordination, lead times, install, and the files we can work from. Written for architects, GCs and brand production teams. For the editorial overview see Capabilities. Project-specific figures are confirmed at feasibility.

Call (832) 906-9009

01

Material families

Recycled polymer composites
Recycled thermoplastic feedstocks for interior features and short-lifecycle installations. Colourable in the mass. Closed-loop recyclable.
Fiber-reinforced thermoplastics
Higher-stiffness formulations for pieces where mass, span or loading require it. Structural role confirmed with engineer of record.
Translucent & specialty formulations
Light-transmissive and specialty polymer blends for feature and luminous elements. Project-specific.
Elastomers & tactile finishes
Soft-touch surfaces for seating, tactile objects and specific interior applications.

02

Print envelope & scale

Element scale
Large-format continuous printing at architectural scale. Maximum envelope for a specific project is confirmed at feasibility, based on geometry, material and site access.
Modular assemblies
Larger works are sectioned into engineered modules for shipping and site assembly.
Minimum viable
Sub-metre object work is directed to our furniture and object program.
Layer resolution
Tuned per material and finish target. Available upon request.

03

Finishes

As-printed
Expressed layering, honest to the process.
Sanded / honed
Layer ribs softened or removed for a matte or satin architectural finish.
Pigmented in the mass
Colour developed through the section — no chip-through risk.
Coated
Standard architectural coating schedules: matte, satin, gloss and metallic. Finish confirmed on physical mock-up.

04

Indoor / outdoor use

Interior
Supported across our material families.
Exterior
Exterior suitability depends on material family, coating strategy, exposure and site conditions — evaluated and documented per project with the material supplier and engineer of record.
Temporary / touring
Polymer families with appropriate topcoats can be scoped for touring installs and activations.

05

Fire rating & code

Approach
Fire performance is developed on a project basis with supplier documentation and, where required, coordinated with the code consultant and Authority Having Jurisdiction.
Documentation
Material data, test reports and coating specifications are compiled for AHJ review. Available upon request.

06

Structural coordination

Design coordination
LOOPFORM coordinates directly with the project architect and engineer of record on geometry, connections and loading.
Analysis
In-studio geometry and DfM analysis on every architectural element; structural stamping is provided by the project engineer of record.
Loads
Wind, seismic, live and impact loads engineered per project location and application.

07

Lead times

Furniture / object
Typical range 4 – 10 weeks, project dependent
Retail programs
Typical range 5 – 9 weeks, project dependent
Expo & activation
Typical range 6 – 10 weeks, project dependent
Architectural feature
Typical range 6 – 14 weeks, project dependent
Façade & large architectural
Longer lead times including engineering coordination. Confirmed at feasibility.

08

Installation

Studio-led
Our crew handles rigging, install and final finishing on architectural work.
Partner-led
Retail rollouts ship with visual playbooks for local install teams.
Site coordination
We coordinate with GC, MEP and lighting trades from shop drawing through hand-off.

09

Files we accept

Preferred
Common industry-standard 3D formats. Confirm specifics with our team.
Also accepted
BIM, IFC, DWG, PDF construction sets
Point clouds & scans
Point-cloud and scan formats accepted — we build parametric geometry to match site conditions.
From sketch
No file? We start from hand sketches or a brief.

Have a live project? Send the file.

Call (832) 906-9009